GURU® W-S Waterproofing Band is a flexible 20 mil seam tape for reinforcing membrane joints, floor-to-wall connections, and changes of plane. Designed for GURU WATER-STOP and G-FLEX systems, it helps maintain continuous waterproof protection in showers, steam showers, wet rooms, balconies, terraces, and other tiled areas.

$54.59
MPN: IGU6100
Free Shipping Available
Ships securely. Checkout protected.

Recommended Add-Ons

You May Also Need

Gurus Water-Stop Inside & Outside Corners
GURU USA
GURU Water-Stop Corners
Pre-Formed Shower Waterproofing Corners for 90° Transitions
$15.08

At a Glance

Quick Decision Guide

Band Size 5-1/2" × 65' 8"
Thickness 20 mil
Application Seam & Transition Reinforcement
Installation Interior & Exterior
Compatible System GURU W-S Waterproofing System
Waterproofing Standard ANSI A118.10
Crack Isolation Standard ANSI A118.12
Common Uses Showers, Steam Rooms, Balconies & Terraces

Why Choose This Product

Key Benefits

Waterproof Seam Protection

Reinforces membrane seams and joints to help maintain a continuous waterproof barrier

Shower Seam Tape

Covers floor-to-wall and wall-to-wall transitions in showers and wet areas

Flexible 20 Mil Band

Conforms to changes of plane and other critical waterproofing details

System Compatibility

Integrates with GURU WATER-STOP and G-FLEX membrane systems

Interior & Exterior Use

Suitable for residential and commercial tile applications

ANSI Compliance

Meets ANSI A118.10 waterproofing and ANSI A118.12 crack isolation requirements

Product Information

Product Details

Specifications

Brand
GURU®
Part Number
IGU6100
UPC
8436540769404
Product Type
Waterproofing Band
Band Dimensions
5-1/2" × 65' 8"
Thickness
20 mil
Material Type
GURU W-S Waterproof Membrane
Application
Waterproof Seam, Joint & Transition Reinforcement
Compatible System
GURU W-S Waterproofing System
Installation Areas
Interior & Exterior
Suitable Applications
Showers, Steam Rooms, Balconies, Terraces
Seam Reinforcement
Waterproof Seams, Joints & Changes of Plane
Low Permeability
Resists Moisture Penetration
Standards
ANSI A118.10, ANSI A118.12
Code Compliance
TCNA, UPC, Canadian Plumbing Code

About This Product

Waterproofing Band for Seams and Joints

GURU® W-S Waterproofing Band reinforces membrane seams, joints, and changes of plane to help maintain a continuous waterproof barrier beneath tile. This flexible waterproofing seam tape covers vulnerable connections where separate waterproofing surfaces meet, helping protect showers, wet rooms, and other moisture-exposed tile assemblies.

Flexible Shower Seam Tape for Wet Areas

Made from the same 20 mil material as GURU W-S Membrane, the band conforms to floor-to-wall connections, wall-to-wall transitions, and other critical waterproofing details. Its low-perm construction supports consistent moisture protection in showers, steam showers, balconies, terraces, kitchens, and other residential or commercial tile applications.

Interior and Exterior Waterproofing Protection

W-S Band integrates with GURU WATER-STOP membrane assemblies and can also reinforce G-FLEX sheet joints when used with the approved bonding material. Suitable for interior and exterior applications, it meets ANSI A118.10 waterproofing and ANSI A118.12 crack isolation requirements for added confidence in the completed tile assembly.

Product Resources

Documentation & Downloads

Common Questions

Frequently Asked Questions

What is GURU W-S Waterproofing Band used for?

GURU W-S Band is used to reinforce waterproofing membrane seams, joints, floor-to-wall connections, wall-to-wall transitions, and other changes of plane. It bridges adjoining waterproofing surfaces so the completed tile assembly can maintain continuous moisture protection across areas that are more vulnerable to water intrusion.

Is GURU W-S Band self-adhesive?

No. W-S Band is a bonded waterproofing seam tape rather than a peel-and-stick product. It must be embedded with the bonding material specified for the waterproofing system. Pressing the band into a complete, even bond helps remove trapped air and maintain waterproof protection across the joint.

Where should waterproofing seam tape be installed?

Center the waterproofing band over membrane seams and joints so it covers both adjoining surfaces. It is commonly used at floor-to-wall and wall-to-wall transitions and other changes of plane. Placement, bonding material, coverage, and overlap requirements should follow the current GURU instructions for the specific waterproofing assembly.

Can W-S Band be used in showers and steam showers?

Yes. W-S Band is designed for waterproofing details in showers, steam showers, wet rooms, and other moisture-exposed tile assemblies. Its flexible, low-perm WATER-STOP construction helps maintain system continuity at seams and transitions when the band is properly bonded and incorporated into the complete waterproofing system.

Which GURU waterproofing systems are compatible with W-S Band?

W-S Band is designed for WATER-STOP membrane assemblies and can also seal G-FLEX sheet joints when installed with the approved GURU bonding material. Follow the instructions for the specific membrane system to ensure the band is fully bonded and the adjoining waterproofing surfaces are properly prepared.

Can GURU W-S Band be used outdoors?

Yes. W-S Band is suitable for approved interior and exterior waterproofing applications, including wet-area walls and floors, balconies, terraces, kitchens, and similar tiled spaces. The supporting assembly, bonding material, and exposed conditions must meet GURU requirements for the intended residential or commercial installation.

What is GURU W-S Waterproofing Band made from?

W-S Band is made from the same flexible, multilayer WATER-STOP membrane used in GURU bonded waterproofing systems. Its 20 mil construction provides waterproof coverage without excessive buildup at seams and transitions, while the membrane surface supports secure bonding within the completed tile assembly.

Which standards does GURU W-S Band meet?

W-S Band uses WATER-STOP membrane material that meets ANSI A118.10 waterproofing and ANSI A118.12 crack isolation requirements. GURU also references the TCNA Handbook, Uniform Plumbing Code, and National Plumbing Code of Canada for applicable waterproofing assemblies. Always follow current local codes and manufacturer instructions.