At a Glance
Why Choose This Product
Heats the concrete mass for extended heat release
Suitable for primary heating, thermal storage and frost heave protection
Cable spacing can be changed to meet project heating requirements
Provides a one-point electrical connection without a return cable
Designed for installation within building foundations and slabs
Available in lengths and outputs for different project requirements
Product Information
Warmup® In-Slab Cable is an electric heating cable designed for embedding in concrete foundations to provide primary heating and thermal storage. The system heats the concrete mass so stored heat can be released over an extended period, making it particularly useful for buildings using solar power or time-of-use electricity rates.
The WODH cable can be installed in dirt or sand beds or secured to lightweight mesh before the concrete foundation is poured. Applications include residential basement heating, commercial slab heating, and frost heave protection for slabs exposed to cold temperatures.
The twin-conductor design eliminates the need to return the cable to the connection point and is constructed to cancel electromagnetic field interference. Each cable includes a factory-attached 16 ft. cold lead for connection outside the heated area.
Heating output can be adjusted by changing the spacing between cable runs to meet project requirements. Closer spacing provides greater heat output for primary in-slab heating, while wider spacing can be used for lower-output applications such as frost heave protection. Cable runs must be spaced at least 3" apart.
In-slab heating systems should be sized according to the building's calculated heat loss and intended charging period. Installed cable capacity must exceed the building heat loss when the system operates for only part of the day, making proper system design important for thermal storage applications.
Common Questions
The cable is designed for primary in-slab heating, thermal storage, and frost heave protection in residential and commercial applications.
The cable can be installed in dirt or sand beds or secured to lightweight mesh and embedded within a concrete foundation pour.
Spacing depends on the required heating output. The minimum spacing between cable runs is 3". System spacing and capacity should be determined according to the heating requirements of the project.
Yes. Thermal storage is one of its primary applications. The cable heats the concrete mass so stored heat can be released over an extended period.
Yes. The cable can provide lower-output slab heating for frost heave protection in commercial and other cold-temperature applications.
Yes. Warmup recommends determining the building heat loss when planning cable quantity and heating output. Thermal storage systems may require installed capacity above the calculated heat loss depending on the daily charging period.
No. The WODH cable should not contact combustible material. Where installed above wood underlayment or insulation panels, it can be raised using metal lath or fiberglass mesh.